Beginning plate processing unit

Processing capacity: 450~500 yuan/hour

Maximum amount of plate arrangement: 53 plate arrangement stations, 53 loading trolley, 53 hoisting stations

Plate spacing: 105mm

The spacing error between the cathode rows arranged by the alignment conveyor is ≤±1.5mm, the cumulative plate spacing error in an electrolytic cell is ≤2.5mm, the plate overhang is ≤±6.5mm, the plate flatness is ≤±6.5mm, the plate flatness is ≤±6.5mm, the plate overhang is more than 90%. Ear weight: ear riveted firmly, deviation from the design value ±2mm, at the same time, the upper edge of the ear must be straight, the height difference between the two ears is not more than 5mm, tensile rate ≥98%.

Equipment noise: ≤65 db at the door of the unit

Power supply requirements:

1) Power supply: three-phase AC380V+N+PE, 50HZ

2) Control power supply: AC220V, 50Hz; DC24V

3) Installed power: ~ 90kW

Hydraulic system pressure: maximum pressure 12Mpa

Compressed air pressure: 0.4 ~ 0.6mpa Gas volume: 4Nm3/min

1. Electric copper washing unit

Unit capacity: 550 /h

Washing effect: the cathode copper surface must be clean, no adhesion of electrolytic residue, no crystallization of copper sulfate (including ear crevices), no other attachments.

Washing water temperature: >70oC, washing nozzle is smooth, the Angle is correct, regularly replace the washing water in the tank

Equipment functions: the whole tank 53 pieces of electric copper high-pressure warm water washing, extracting conductive rod, ~20 pieces of stacking, weighing, baling, using forklift truck to carry out ø

Technical requirements:

1) The electric copper is packed into stacks (20 pieces) and transported out by forklift truck

2) Weighing accuracy: ≤±2kg

3) The number of receiving plate slots: ≥1.5 slots about 80 pieces

2. Anodic shaping unit

(1) Processing capacity 200-450 pieces of anode/hour (optional)

(2) Technical performance parameters

1) 100mm from the center of the plate with the same name (optional)

2) The number of positive plate blocks per slot is 55 (optional)

(3) Design description:

1) This equipment has the functions of anodic flattening, ear correcting, ear milling and row spacing, and the side milling ear is required separately;

2) anodic verticality: after the ear is milling, the ear is used to hang the anode naturally, and 95% of the anodic deviation from the perpendicular is less than or equal to 3mm;

3) After the pressure shaping of the entire anode plate surface, the Angle diagonal measurement shows that the straightness of the anode mold surface is less than or equal to 3mm;

4) Pole distance: the distance between the same plate is 100mm. After adjusting the distance, the side measure is carried out from the ear of the anode mold surface. The distance of each is less than 1.5mm, and the total distance is less than 2.5mm;

5) Noise: less than 85dB;

6) Weighing accuracy: ±1.5kg

1626751683602789.jpg